Heraeus Vötsch temperature test chamber, temperature range -30 °C to +125 °C, 680 liters, model VLM Weiss
Vötsch VLM 3068/S
Heraeus Vötsch temperature test chamber, temperature range -30 °C to +125 °C, 680 liters, model VLM
Weiss
Vötsch VLM 3068/S
Состојба
Користено
Локација
Borken 

Основни податоци
- Ознака на машината:
- Heraeus Vötsch temperature test chamber, temperature range -30 °C to +125 °C, 680 liters, model VLM
- Произведувач:
- Weiss
- Модел:
- Vötsch VLM 3068/S
- Состојба:
- половен
Цена и локација
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A22185287
- Референтен број:
- 23960
- Ажурирање:
- последно на 15.10.2026
Опис
Vötsch
Type: VLM 3068/S
Vötsch Temperature Test Chamber VLM 3068/S, Air-Cooled
(Top-loading test chambers for construction materials)
Control Panel
The control panel is mounted on a console on the temperature test chamber. All control and operating commands can be activated by simply touching the function symbols. The operating manual for the control panel is included.
Main Switch
The main switch is located at the front of the temperature test chamber.
Hfodpszgbmiofx Anpen
Air Handling Unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control. In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air deflectors on the long sides.
Feedthroughs
The temperature test chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber. Feedthrough at the front 2 x 82 mm diameter, at the rear 1 x 85 mm diameter.
Internal Dimensions: Width 2000 mm, Depth 570 mm, Height 600 mm
External Dimensions: Width 3000 mm, Depth 870 mm, Height 1060 mm
Technical Data:
Data for Mechanical Load:
Max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for Temperature Tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the useful space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for Operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Fuse on customer side 16A slow-blow
Temperature Test Chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Type: VLM 3068/S
Vötsch Temperature Test Chamber VLM 3068/S, Air-Cooled
(Top-loading test chambers for construction materials)
Control Panel
The control panel is mounted on a console on the temperature test chamber. All control and operating commands can be activated by simply touching the function symbols. The operating manual for the control panel is included.
Main Switch
The main switch is located at the front of the temperature test chamber.
Hfodpszgbmiofx Anpen
Air Handling Unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control. In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air deflectors on the long sides.
Feedthroughs
The temperature test chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber. Feedthrough at the front 2 x 82 mm diameter, at the rear 1 x 85 mm diameter.
Internal Dimensions: Width 2000 mm, Depth 570 mm, Height 600 mm
External Dimensions: Width 3000 mm, Depth 870 mm, Height 1060 mm
Technical Data:
Data for Mechanical Load:
Max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for Temperature Tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the useful space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for Operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Fuse on customer side 16A slow-blow
Temperature Test Chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Овие огласи исто така може да ве заинтересираат.
Успешно
Вашата порака е испратена.
Мал оглас
Sonsbeck
1.612 km
Hegewald & Peschke/HessH2,5TMNI
Успешно
Вашата порака е испратена.
Мал оглас
Sonsbeck
1.612 km
Hegewald & PeschkeH5TMCI
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.603 km
ZwickRoellEC76G 1-1-2-0 361763
Успешно
Вашата порака е испратена.
Мал оглас
Wuppertal
1.542 km
Darto GmbHPM50 Universalprüfmaschine
Успешно
Вашата порака е испратена.
Мал оглас
Kusel
1.420 km
ShimadzuUX4200H
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
Sartorius513
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
Sartorius Tare CPA34001S Analytical BalanceCPA34001S
Успешно
Вашата порака е испратена.
Мал оглас
Schweinfurt
1.292 km
ZwickRoellBX1-EZ010.A1K-000
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.603 km
VLMKorrosionsprüfschrank
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
Sartorius Tare ENTRIS2202-1S BalanceSartorius Tare ENTRIS2202-1S Balance
Вашиот оглас беше успешно избришан
Се случи грешка