Thermo Fisher Flash 2000 CHNS/O Analyzer with 2x AI AS 1310 AutosamplerThermo Fisher Scientific
Thermo Fisher Flash 2000
Thermo Fisher Flash 2000 CHNS/O Analyzer with 2x AI AS 1310 Autosampler
Thermo Fisher Scientific
Thermo Fisher Flash 2000
VB додава се ДДВ
6.500 €
Состојба
Користено
Локација
Borken 

Основни податоци
- Ознака на машината:
- Thermo Fisher Flash 2000 CHNS/O Analyzer with 2x AI AS 1310 Autosampler
- Произведувач:
- Thermo Fisher Scientific
- Модел:
- Thermo Fisher Flash 2000
- Состојба:
- половен
Цена и локација
VB додава се ДДВ
6.500 €
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A21755313
- Референтен број:
- 25147
- Ажурирање:
- последно на 15.10.2026
Опис
Thermo Fisher Scientific
Thermo Fisher Scientific Flash 2000
CHNS O Analyzer with 2 x AI AS 1310 Autosamplers
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer.
The unit is equipped with two AI AS 1310 autosamplers.
It is designed for automated laboratory operation.
Iodpfey D Sqvex Aa Ujtn
The system is used for elemental analysis in the laboratory.
Sample introduction is performed via the installed autosamplers.
This enables continuous and automated operation.
Equipment and features:
Thermo Fisher Scientific Flash 2000
CHNS O Analyzer
2 x AI AS 1310 Autosamplers
Front display with status fields for operating states
Gas connections for He and O2
RS232 interfaces and other device interfaces
Connections for autosamplers and additional modules
Power connection 230 V
Accessories and parts as shown in the pictures
Technical data:
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Voltage: 230 V AC
Frequency: 50-60 Hz
Fuse: 2 x 6 A
Power: 1400 VA
Autosampler:
Model: AI AS 1310
Supply: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions (approx.):
Main unit: Width approx. 55 to 60 cm
Depth approx. 55 to 65 cm
Height approx. 50 to 60 cm
Overall width with 2 autosamplers approx. 100 to 120 cm
Weight (approx.):
Main unit: approx. 45 to 60 kg
Autosampler: approx. 8 to 12 kg each
Total: approx. 60 to 80 kg
Condition:
Used, with typical signs of wear and tear due to age and use.
The condition corresponds to the pictures.
Scope of delivery:
Flash 2000 Analyzer
2 x Autosamplers
Accessories and cables as shown in the pictures
Important note:
All information has been provided to the best of our knowledge, based on the pictures,
nameplates, and manufacturer information.
The table shown in the photos and any other items not explicitly mentioned
are not included in the sale.
Shipping is possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Thermo Fisher Scientific Flash 2000
CHNS O Analyzer with 2 x AI AS 1310 Autosamplers
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer.
The unit is equipped with two AI AS 1310 autosamplers.
It is designed for automated laboratory operation.
Iodpfey D Sqvex Aa Ujtn
The system is used for elemental analysis in the laboratory.
Sample introduction is performed via the installed autosamplers.
This enables continuous and automated operation.
Equipment and features:
Thermo Fisher Scientific Flash 2000
CHNS O Analyzer
2 x AI AS 1310 Autosamplers
Front display with status fields for operating states
Gas connections for He and O2
RS232 interfaces and other device interfaces
Connections for autosamplers and additional modules
Power connection 230 V
Accessories and parts as shown in the pictures
Technical data:
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Voltage: 230 V AC
Frequency: 50-60 Hz
Fuse: 2 x 6 A
Power: 1400 VA
Autosampler:
Model: AI AS 1310
Supply: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions (approx.):
Main unit: Width approx. 55 to 60 cm
Depth approx. 55 to 65 cm
Height approx. 50 to 60 cm
Overall width with 2 autosamplers approx. 100 to 120 cm
Weight (approx.):
Main unit: approx. 45 to 60 kg
Autosampler: approx. 8 to 12 kg each
Total: approx. 60 to 80 kg
Condition:
Used, with typical signs of wear and tear due to age and use.
The condition corresponds to the pictures.
Scope of delivery:
Flash 2000 Analyzer
2 x Autosamplers
Accessories and cables as shown in the pictures
Important note:
All information has been provided to the best of our knowledge, based on the pictures,
nameplates, and manufacturer information.
The table shown in the photos and any other items not explicitly mentioned
are not included in the sale.
Shipping is possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Овие огласи исто така може да ве заинтересираат.
Успешно
Вашата порака е испратена.
Мал оглас
Olsztyn
1.358 km
Shimadzu LC-40Dx3Triple Quad 6500+
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
Heidolph MR Hei-standard Magnetic Hotplate StirrerHeidolph MR Hei-standard Magnetic Hotplate Stirrer
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
WatersACQUITY
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
WatersAquity H-Class
Успешно
Вашата порака е испратена.
Мал оглас
Kreuzau
1.549 km
BelimedWD 290
Успешно
Вашата порака е испратена.
Мал оглас
Töltéstava
741 km
IKARO 10
Успешно
Вашата порака е испратена.
Мал оглас
Duxford
2.003 km
MilliporeAFS 15E
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.603 km
Thermo Fisher ScientificThermo Fisher ARCTIC A25 Kältethermostate
Вашиот оглас беше успешно избришан
Се случи грешка