Vötsch
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Prjdpfjxbrkhex Abgjd
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Prjdpfjxbrkhex Abgjd
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2012
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Вашиот оглас беше успешно избришан
Се случи грешка