Temperature shock test chamberVötsch
VT 7012 S2
Temperature shock test chamber
Vötsch
VT 7012 S2
VB додава се ДДВ
11.025 €
година на производство
2005
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Temperature shock test chamber
- Произведувач:
- Vötsch
- Модел:
- VT 7012 S2
- Година на производство:
- 2005
- Состојба:
- многу добро (користено)
Цена и локација
VB додава се ДДВ
11.025 €
- Локација:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE

Повикајте
Детали за понудата
- ID на огласот:
- A12811967
- Референтен број:
- 31747
- Ажурирање:
- последно на 01.08.2025
Опис
Vötsch Shock Test Chamber VT 7012 S2
Systems for Extreme Temperature Changes
Temperature shock testing tests the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are exposed to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclic loads and the accelerated aging caused by temperature changes can reveal weak points in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the elevator car
Car load capacity: 50 kg for the VT3 7012 S2
All-round gratings in the elevator car secure the test specimens
High air circulation rate, short temperature cycling times, and even temperature distribution in the test chamber
Hot chamber can be used as a temperature storage device, while the cold chamber can be used as a temperature cycling device
Touch panel for convenient editing of simulation programs with graphic display
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test room dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Year of manufacture: 2005
Protection class
Device: IP 42
Control panel: IP 20
Control cabinet: IP 54
Characteristics for temperature tests in single-chamber operation |
Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: +_ 2 K
in steady state
Temperature deviation over space: +_ 2 K
in steady state in the elevator car
Heating rate of hot chamber: 11 K/min
Pjdpfxsph Uz Uj Abxjrc
Cooling rate of cold chamber: K/min
Heating rate of cold chamber: 2 K/min
Cooling rate of hot chamber: K/min
Observation window: 355 x 355 mm
Pipe penetration: 67 mm
Weight: 1000 kg
Find more items - new and used - in our shop!
International shipping costs upon request!
Systems for Extreme Temperature Changes
Temperature shock testing tests the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are exposed to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclic loads and the accelerated aging caused by temperature changes can reveal weak points in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the elevator car
Car load capacity: 50 kg for the VT3 7012 S2
All-round gratings in the elevator car secure the test specimens
High air circulation rate, short temperature cycling times, and even temperature distribution in the test chamber
Hot chamber can be used as a temperature storage device, while the cold chamber can be used as a temperature cycling device
Touch panel for convenient editing of simulation programs with graphic display
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test room dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Year of manufacture: 2005
Protection class
Device: IP 42
Control panel: IP 20
Control cabinet: IP 54
Characteristics for temperature tests in single-chamber operation |
Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: +_ 2 K
in steady state
Temperature deviation over space: +_ 2 K
in steady state in the elevator car
Heating rate of hot chamber: 11 K/min
Pjdpfxsph Uz Uj Abxjrc
Cooling rate of cold chamber: K/min
Heating rate of cold chamber: 2 K/min
Cooling rate of hot chamber: K/min
Observation window: 355 x 355 mm
Pipe penetration: 67 mm
Weight: 1000 kg
Find more items - new and used - in our shop!
International shipping costs upon request!
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Овие огласи исто така може да ве заинтересираат.
мал оглас
Borken
1.603 km
VötschVT 7012 S2
мал оглас
Borken
1.603 km
VötschVT 7012 S2
мал оглас
Borken
1.603 km
VötschVT 7012 S2
мал оглас
Borken
1.603 km
VötschVT 7012 S2
мал оглас
Borken
1.603 km
VötschVT 7012 S2 (6603)
Вашиот оглас беше успешно избришан
Се случи грешка