Climatic test chamber 800 L, -55°C to +180°CWeiss
ClimeEvent C/800/55a/25/S 25K/min
Climatic test chamber 800 L, -55°C to +180°C
Weiss
ClimeEvent C/800/55a/25/S 25K/min
година на производство
2020
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Climatic test chamber 800 L, -55°C to +180°C
- произведувач:
- Weiss
- година на производство:
- 2020
- Состојба:
- многу добро (користено)
Цена и локација
- Локација:
- Einsteinstraße 8a, 46325 Borken, DE

Повикајте
Детали за понудата
- ID на огласот:
- A19821050
- Референтен број:
- 24761
- ажурирање:
- последно на 22.08.2025
Опис
Weiss
Type: C/800/55a/25/S
Nsdpfx Ajw R Rt Iofnelh
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Type: C/800/55a/25/S
Nsdpfx Ajw R Rt Iofnelh
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)