Climate chamber with humidity 34 litersWeiss
WKL 34/60 -60°C bis 150°C
Climate chamber with humidity 34 liters
Weiss
WKL 34/60 -60°C bis 150°C
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Climate chamber with humidity 34 liters
- Произведувач:
- Weiss
- Состојба:
- многу добро (користено)
Цена и локација
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A16211179
- Референтен број:
- 24134
- Ажурирање:
- последно на 15.11.2024
Опис
White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Ibjdpfx Aaetr Dinofjd
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Ibjdpfx Aaetr Dinofjd
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2012
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Вашиот оглас беше успешно избришан
Се случи грешка