Real-time PCR machineApplied Biosystems
ViiA7
Real-time PCR machine
Applied Biosystems
ViiA7
фиксна цена додава се ДДВ
8.500 €
Состојба
Користено
Локација
Borken 

Податоци за машината
- Ознака на машината:
- Real-time PCR machine
- Произведувач:
- Applied Biosystems
- Модел:
- ViiA7
- Состојба:
- многу добро (користено)
Цена и локација
фиксна цена додава се ДДВ
8.500 €
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A22150267
- Референтен број:
- 23464
- Ажурирање:
- последно на 18.06.2026
Опис
Applied Biosystems ViiA7
Here we offer an Applied Biosystems ViiA7.
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds of reaching the target temperature
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100 μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target amounts in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support are provided by Life Technologies)
Remote notification: Notifies the user by email when the run starts, stops, or is aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates
Ijdpfozd Ud Nox Ak Doth
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used
Scope of supply: (See image)
(Changes and errors in technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Here we offer an Applied Biosystems ViiA7.
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds of reaching the target temperature
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100 μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target amounts in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support are provided by Life Technologies)
Remote notification: Notifies the user by email when the run starts, stops, or is aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates
Ijdpfozd Ud Nox Ak Doth
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used
Scope of supply: (See image)
(Changes and errors in technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.