Measuring system Mass flowmeterEndress+Hauser
PROMASS 83F1H-3967/0
Measuring system Mass flowmeter
Endress+Hauser
PROMASS 83F1H-3967/0
EXW VB додава се ДДВ
6.000 €
Година на производство
2020
Состојба
Користено
Локација
Warszawa 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Measuring system Mass flowmeter
- Произведувач:
- Endress+Hauser
- Модел:
- PROMASS 83F1H-3967/0
- Број на машина:
- AFMAAAABABAA+
- Година на производство:
- 2020
- Состојба:
- многу добро (користено)
- Функционалност:
- целосно функционален
Цена и локација
EXW VB додава се ДДВ
6.000 €
- Локација:
- Marszałkowska 55/73, 00-676 Warszawa, Polska

Повикајте
Детали за понудата
- ID на огласот:
- A21703893
- Референтен број:
- E710E302000
- Ажурирање:
- последно на 15.04.2026
Опис
The Coriolis Mass Flowmeter Proline Promass 83F, manufactured by Promass in 2011, is a precision instrument designed for accurate mass flow measurements in various industrial processes. This model, designated as 83F1H-3967/0 with serial number E710E302000, has a nominal size of DN100 (4 inches) and is equipped with a hygienic process connection DN100 DIN 11851, making it suitable for applications requiring sanitary standards, such as dairy processing.
Constructed from high-grade stainless steels 1.4404/316L and 1.4539/904L, the device offers durability and corrosion resistance. It is rated for a nominal pressure (pnom) of 25 bar and operates in a process temperature range from -50°C to +200°C, with an ambient temperature tolerance from -20°C to +60°C. The flowmeter's housing features IP67 and NEMA/Type 4X protection ratings, ensuring resistance to dust and immersion in water.
Gusdpoy Anhzefx Ad Doa
Sensor calibration includes a K factor of 1.6287 / 51 and a density accuracy of 0.0005 g/cc. The surface finish meets hygienic standards, featuring a roughness of 0.8 µm (150 grit).
The unit is powered by a voltage range of 20-55 VAC or 16-62 VDC, consuming 15 VA/W at a frequency of 50-60 Hz. The housing shows some surface wear and minor dents, and the label exhibits slight wear but remains mostly legible. It is mounted on a wooden pallet and is equipped with attached braided cables with yellow markings and black cable ties. Some dust accumulation is visible on the flowmeter body, indicative of prior use.
This Promass 83F flowmeter is suitable for precision mass flow measurement in the pharmaceutical, chemical, and food industries, particularly where hygienic conditions are required.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Constructed from high-grade stainless steels 1.4404/316L and 1.4539/904L, the device offers durability and corrosion resistance. It is rated for a nominal pressure (pnom) of 25 bar and operates in a process temperature range from -50°C to +200°C, with an ambient temperature tolerance from -20°C to +60°C. The flowmeter's housing features IP67 and NEMA/Type 4X protection ratings, ensuring resistance to dust and immersion in water.
Gusdpoy Anhzefx Ad Doa
Sensor calibration includes a K factor of 1.6287 / 51 and a density accuracy of 0.0005 g/cc. The surface finish meets hygienic standards, featuring a roughness of 0.8 µm (150 grit).
The unit is powered by a voltage range of 20-55 VAC or 16-62 VDC, consuming 15 VA/W at a frequency of 50-60 Hz. The housing shows some surface wear and minor dents, and the label exhibits slight wear but remains mostly legible. It is mounted on a wooden pallet and is equipped with attached braided cables with yellow markings and black cable ties. Some dust accumulation is visible on the flowmeter body, indicative of prior use.
This Promass 83F flowmeter is suitable for precision mass flow measurement in the pharmaceutical, chemical, and food industries, particularly where hygienic conditions are required.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Последен пат онлајн: Вчера
Регистриран од: 2026
8 Огласи онлајн
Испрати барање
Телефон & Факс
+48 882 6... огласи
Вашиот оглас беше успешно избришан
Се случи грешка








