Espec
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
Isdpfx Aaex Iu I Sj Dotr
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
Isdpfx Aaex Iu I Sj Dotr
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2012
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Овие огласи исто така може да ве заинтересираат.
Мал оглас
Borken
1.604 km
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Мал оглас
Borken
1.603 km
TIRATCC 7120
Вашиот оглас беше успешно избришан
Се случи грешка