RS Simulators Temperature Shock Test System ST2K320/45 KRS-Simulatoren
Schocktest
RS Simulators Temperature Shock Test System ST2K320/45 K
RS-Simulatoren
Schocktest
Состојба
Користено
Локација
Borken 

Основни податоци
- Ознака на машината:
- RS Simulators Temperature Shock Test System ST2K320/45 K
- Произведувач:
- RS-Simulatoren
- Модел:
- Schocktest
- Состојба:
- половен
Цена и локација
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A22185487
- Референтен број:
- 24112
- Ажурирање:
- последно на 15.10.2026
Опис
RS Simulators
Type: ST2K320/45 K
Water-cooled shock testing system
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25 % to 75 % relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Hfjdpfxjzgbuts Anpsn
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Type: ST2K320/45 K
Water-cooled shock testing system
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25 % to 75 % relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Hfjdpfxjzgbuts Anpsn
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Овие огласи исто така може да ве заинтересираат.
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.603 km
RS-SimulatorenSchocktest
Успешно
Вашата порака е испратена.
Мал оглас
Wesel
1.603 km
ERBAYE 60 Separierstrecke
Вашиот оглас беше успешно избришан
Се случи грешка