Mass spectrometerWaters
nanoACQUITY UPLCTM G2-S Q-TOF
Mass spectrometer
Waters
nanoACQUITY UPLCTM G2-S Q-TOF
фиксна цена додава се ДДВ
28.000 €
Состојба
Користено
Локација
Borken 

Податоци за машината
Цена и локација
фиксна цена додава се ДДВ
28.000 €
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A22215347
- Референтен број:
- 24455
- Ажурирање:
- последно на 26.06.2026
Опис
HPLC Waters
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow Control Modules
Flow rate of 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates of 0.10 to 5.00 µl/min.
Flow control module
Flow rate of 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples, which it draws from microtiter plates or vials, into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard wash, or it can do so in less than 60 seconds,
including a double standard wash.
The sample manager accepts plates with standard footprint, 5.03” x 3.365”,
which correspond to SBS/ANSI-compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F)
under ambient conditions of 25 °C (77 °F) or less.
Nljdpozg Tzxofx Akvsc
Heating and capture module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient temperature to 65 °C (149 °F).
The column base can be pivoted outwards into any position between 0° and 180°.
In the 0° “home” position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° “away” position, the analytical column can be connected to a mass spectrometer
(on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of the ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used not only for peptide identification
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Operating manual
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data, information are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow Control Modules
Flow rate of 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates of 0.10 to 5.00 µl/min.
Flow control module
Flow rate of 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples, which it draws from microtiter plates or vials, into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard wash, or it can do so in less than 60 seconds,
including a double standard wash.
The sample manager accepts plates with standard footprint, 5.03” x 3.365”,
which correspond to SBS/ANSI-compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F)
under ambient conditions of 25 °C (77 °F) or less.
Nljdpozg Tzxofx Akvsc
Heating and capture module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient temperature to 65 °C (149 °F).
The column base can be pivoted outwards into any position between 0° and 180°.
In the 0° “home” position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° “away” position, the analytical column can be connected to a mass spectrometer
(on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of the ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used not only for peptide identification
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Operating manual
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data, information are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Вашиот оглас беше успешно избришан