Fresenius Vial Pilot A2 Medical Infusion Syringe Pump (Perfusor)Fresenius
Pilot A2
Fresenius Vial Pilot A2 Medical Infusion Syringe Pump (Perfusor)
Fresenius
Pilot A2
VB додава се ДДВ
226 €
Состојба
Користено
Локација
Borken 

Основни податоци
- Ознака на машината:
- Fresenius Vial Pilot A2 Medical Infusion Syringe Pump (Perfusor)
- Произведувач:
- Fresenius
- Модел:
- Pilot A2
- Состојба:
- половен
Цена и локација
VB додава се ДДВ
226 €
- Локација:
- Borken, Германија

Повикајте
Детали за понудата
- ID на огласот:
- A23232142
- Референтен број:
- 74859
- Ажурирање:
- последно на 28.10.2026
Опис
Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In medical practice, the device is used for the continuous, precisely controlled administration of highly potent drugs, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Nsdpfx Adj Af Uyrogewn
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2011
"Everything from one source: We would be happy to offer you a suitable bank financing option for your project."
More items - new and used - can be found in our shop!
International shipping costs on request!
Огласот е автоматски преведен. Можно е да има грешки во преводот.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In medical practice, the device is used for the continuous, precisely controlled administration of highly potent drugs, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Nsdpfx Adj Af Uyrogewn
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2011
"Everything from one source: We would be happy to offer you a suitable bank financing option for your project."
More items - new and used - can be found in our shop!
International shipping costs on request!
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Последен пат онлајн: минатата недела
Регистриран од: 2008
536 Огласи онлајн
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Овие огласи исто така може да ве заинтересираат.
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.611 km
FreseniusPilot A2
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.611 km
FreseniusPilot A2
Успешно
Вашата порака е испратена.
Мал оглас
Borken
1.611 km
FreseniusPilot A2
Вашиот оглас беше успешно избришан
Се случи грешка