Опис
GBS Test Pulse Rev. 3 Pulse Generator for Long-Term Insulation Tests
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
Iodpsu Egz Rsfx Adisal
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
Iodpsu Egz Rsfx Adisal
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2008
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Овие огласи исто така може да ве заинтересираат.
Мал оглас
Kolbuszowa
962 km
Koltex Plastic Recycling SystemsXR 8
Мал оглас
Düngenheim
1.481 km
Abus KransystemeGM2000.5000 H-322.41.9000.3E 130.20
Мал оглас
Soerendonk
1.637 km
Flender / SiemensK2S-2,5
Мал оглас
Wiefelstede
1.648 km
Heuer FrontSpannweite 235 mm
Мал оглас
Германија
1.369 km
Vollert
Мал оглас
Tönisvorst
1.588 km
mitlaufendSPH 150 mm
Вашиот оглас беше успешно избришан
Се случи грешка