Heraeus
Hedpfjzd R Azsx Ac Usnu
Type: HT 7012 S2
Heraeus Shock Test Chamber
Temperature Shock Test Cabinet, Water-Cooled
Two-Chamber Design
Warm Chamber:
The temperature control for the warm chamber ranges from +50°C to +220°C.
Temporal temperature deviation in the center of the usable space: ± 1 K.
Spatial temperature deviation: ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold Chamber:
The temperature control for the cold chamber ranges from -65°C to +70°C.
Temporal temperature deviation in the center of the usable space: ± 1 K.
Spatial temperature deviation: ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Temperature range, warm chamber: +50°C to +220°C.
Temperature range, cold chamber: -80°C to +70°C.
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm.
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm.
Rated power: 10 kW.
Rated current: 25 A.
Voltage: 3/N/PE AC 400 V +6/-10% 50 Hz.
Refrigerant: R404A / R23.
Weight: 1000 kg.
For your safety as a buyer, please note the following information:
The following steps will be carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components.
2. Refilling with refrigerants that comply with legal regulations.
3. Leak test with certificate.
4. After successful inspection, the chambers will undergo a test run, which is monitored with calibrated devices.
Condition: used.
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Hedpfjzd R Azsx Ac Usnu
Type: HT 7012 S2
Heraeus Shock Test Chamber
Temperature Shock Test Cabinet, Water-Cooled
Two-Chamber Design
Warm Chamber:
The temperature control for the warm chamber ranges from +50°C to +220°C.
Temporal temperature deviation in the center of the usable space: ± 1 K.
Spatial temperature deviation: ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold Chamber:
The temperature control for the cold chamber ranges from -65°C to +70°C.
Temporal temperature deviation in the center of the usable space: ± 1 K.
Spatial temperature deviation: ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Temperature range, warm chamber: +50°C to +220°C.
Temperature range, cold chamber: -80°C to +70°C.
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm.
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm.
Rated power: 10 kW.
Rated current: 25 A.
Voltage: 3/N/PE AC 400 V +6/-10% 50 Hz.
Refrigerant: R404A / R23.
Weight: 1000 kg.
For your safety as a buyer, please note the following information:
The following steps will be carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components.
2. Refilling with refrigerants that comply with legal regulations.
3. Leak test with certificate.
4. After successful inspection, the chambers will undergo a test run, which is monitored with calibrated devices.
Condition: used.
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)