Climate test chamber 600 liters with humidityWeiss
WK3-600/0-M -5°C bis +90°C
Climate test chamber 600 liters with humidity
Weiss
WK3-600/0-M -5°C bis +90°C
Состојба
Користено
Локација
Borken 

Податоци за машината
- Ознака на машината:
- Climate test chamber 600 liters with humidity
- Произведувач:
- Weiss
- Состојба:
- многу добро (користено)
Цена и локација
- Локација:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A22270542
- Референтен број:
- 24892
- Ажурирање:
- последно на 06.07.2026
Опис
Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Pjdpfx Aloziywrsiegr
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Pjdpfx Aloziywrsiegr
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Испрати барање
Телефон & Факс
+49 2861 ... огласи
Овие огласи исто така може да ве заинтересираат.
Мал оглас
Güglingen
1.295 km
Hitema ENR 075 Prozess Kaltwassersatz
Мал оглас
Velen
1.603 km
METALLOPremium
Мал оглас
Kirchheim bei München
1.072 km
INTOSFNGP 40
Мал оглас
Egenhofen
1.113 km
AircraftAIRSTAR 853/270/10V ohne AD 2000
Мал оглас
Bopfingen
1.199 km
DietheiMD 50 d(igital)
Мал оглас
Warngau
1.053 km
DECKELDECKEL FP4A
Мал оглас
Frasdorf
1.016 km
MacmonM.100 NC mit TNC 124 Haidenhain
Мал оглас
Mindelheim
1.138 km
OptimumUF 100
Мал оглас
Германија
1.369 km
Friedrich DeckelFP4A
Мал оглас
Baienfurt
1.178 km
KolbStudioLine M
Вашиот оглас беше успешно избришан
Се случи грешка