Bronchoscopy washing machineBHT
INNOVA E3
Bronchoscopy washing machine
BHT
INNOVA E3
VB додава се ДДВ
6.640 €
година на производство
2013
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Bronchoscopy washing machine
- Произведувач:
- BHT
- Модел:
- INNOVA E3
- Година на производство:
- 2013
- Состојба:
- добра (користена)
Цена и локација
VB додава се ДДВ
6.640 €
- Локација:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A7725170
- Референтен број:
- 25755
- Ажурирање:
- последно на 06.08.2025
Опис
BHT INNOVA E3 Professional Bronchoscope Washer
INNOVA – Professional Endoscope Washer for Practices and Small Clinics
The INNOVA™ E3s is the world's best-selling BHT endoscope washer. This endoscope washer is compact and offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing, a total of 10 to 20 endoscope reprocessings are possible daily. This makes it the perfect solution for private medical practices and small clinics that value safe hygiene, efficiency, and reliability.
Reliability and maximum cleanliness in every cycle:
Compliant with DIN EN ISO 15883-1/-4 and the guidelines
of the Robert Koch Institute (RKI), and with many additional functions, e.g., thermal self-disinfection at 90°C according to DIN EN ISO 15883-4, 4.8.1.
- Flexible in combination with another INNOVA® E2 or E3 for 30 to 40 reprocessings daily.
- Suitable for both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercially available endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single-channel connection or patented pressure chamber available.
- Thermal reprocessing option, e.g., for multiple biopsy forceps, polyp loops, etc.
- Thermal disinfection of the final rinse water as recommended by the Robert Koch Institute (RKI) for the DH version.
- Secure documentation and traceability through batch control. User and endoscope identification via barcode scanner.
Pedpsin Edwefx Abgjrd
- Data output via printer, data logger, or computer interface. Easy integration into existing IT systems
Number of endoscopes: For 2 endoscopes or 4 ENTs
Hygienic design: Hygienic workflow, single-door
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single-channel monitoring system (CMS): No
Chemistry Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC (filter solution, for
glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger as standard. Printer as standard.
Optional scanner/IT interface
Thermal reprocessing of instruments at 90°C: Available with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse rating: 3 x 20 A
Year of manufacture: January 19, 2013
Item condition: used
Find more items - new and used - in our shop!
International shipping costs on request!
INNOVA – Professional Endoscope Washer for Practices and Small Clinics
The INNOVA™ E3s is the world's best-selling BHT endoscope washer. This endoscope washer is compact and offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing, a total of 10 to 20 endoscope reprocessings are possible daily. This makes it the perfect solution for private medical practices and small clinics that value safe hygiene, efficiency, and reliability.
Reliability and maximum cleanliness in every cycle:
Compliant with DIN EN ISO 15883-1/-4 and the guidelines
of the Robert Koch Institute (RKI), and with many additional functions, e.g., thermal self-disinfection at 90°C according to DIN EN ISO 15883-4, 4.8.1.
- Flexible in combination with another INNOVA® E2 or E3 for 30 to 40 reprocessings daily.
- Suitable for both glutaraldehyde and peracetic acid from a wide range of suppliers.
- Suitable for commercially available endoscopes from Fuji, Olympus, Pentax, Storz, and Wolf.
- Single-channel connection or patented pressure chamber available.
- Thermal reprocessing option, e.g., for multiple biopsy forceps, polyp loops, etc.
- Thermal disinfection of the final rinse water as recommended by the Robert Koch Institute (RKI) for the DH version.
- Secure documentation and traceability through batch control. User and endoscope identification via barcode scanner.
Pedpsin Edwefx Abgjrd
- Data output via printer, data logger, or computer interface. Easy integration into existing IT systems
Number of endoscopes: For 2 endoscopes or 4 ENTs
Hygienic design: Hygienic workflow, single-door
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single-channel monitoring system (CMS): No
Chemistry Glutaraldehyde / Peracetic Acid: Both possible: DH version (with boiler, for glutaraldehyde) or DC (filter solution, for
glutaraldehyde or peracetic acid)
Documentation and integration: Yes, interface for printer/data logger as standard. Printer as standard.
Optional scanner/IT interface
Thermal reprocessing of instruments at 90°C: Available with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Connected load: 11 kW. Fuse rating: 3 x 20 A
Year of manufacture: January 19, 2013
Item condition: used
Find more items - new and used - in our shop!
International shipping costs on request!
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Вашиот оглас беше успешно избришан
Се случи грешка






















