Bioer Quant Gene 9600 Fluorescent Quantitative Detection SystemBioer Quant Gene 9600
Gene 9600
Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
Bioer Quant Gene 9600
Gene 9600
фиксна цена додава се ДДВ
1.020 €
Состојба
Користено
Локација
Duxford 

Податоци за машината
- Ознака на машината:
- Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
- Произведувач:
- Bioer Quant Gene 9600
- Модел:
- Gene 9600
- Состојба:
- половен
Цена и локација
фиксна цена додава се ДДВ
1.020 €
- Локација:
- Duxford, UK

Повикајте
Детали за понудата
- ID на огласот:
- A20124805
- Референтен број:
- PR-001.SR4C
- Ажурирање:
- последно на 29.07.2026
Опис
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Blodpoxhgfgsfx Ac Hjk
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Blodpoxhgfgsfx Ac Hjk
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2019
813 Огласи онлајн
Испрати барање
Телефон & Факс
+44 20 38... огласи
Овие огласи исто така може да ве заинтересираат.
Мал оглас
Świdno
1.044 km
Mercedes-Benzsprinter 318
Мал оглас
Győr
750 km
Instrumentation LaboratoryGEM Premier 4000
Мал оглас
Piskorzów
1.096 km
SystecDE - 150
Мал оглас
Burladingen
1.243 km
SystecVX-150
Вашиот оглас беше успешно избришан