Pacific Scientific 3313LL Met One Particle CounterPacific Scientific
3313LL Met One
Pacific Scientific 3313LL Met One Particle Counter
Pacific Scientific
3313LL Met One
Состојба
Користено
Локација
Duxford 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Pacific Scientific 3313LL Met One Particle Counter
- Произведувач:
- Pacific Scientific
- Модел:
- 3313LL Met One
- Состојба:
- половен
Цена и локација
- Локација:
- Duxford, UK

Повикајте
Детали за понудата
- ID на огласот:
- A20502585
- Референтен број:
- 23241.SR11B
- Ажурирање:
- последно на 11.11.2025
Опис
This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
Chjdexv Ab Hjpfx Agbjf
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
Chjdexv Ab Hjpfx Agbjf
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2019
Испрати барање
Телефон & Факс
+44 20 38... огласи
Вашиот оглас беше успешно избришан
Се случи грешка