High voltage adapter voltmeter adapterChilworth
JCI 164
High voltage adapter voltmeter adapter
Chilworth
JCI 164
VB додава се ДДВ
1.600 €
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- High voltage adapter voltmeter adapter
- Произведувач:
- Chilworth
- Модел:
- JCI 164
- Состојба:
- многу добро (користено)
Цена и локација
VB додава се ДДВ
1.600 €
- Локација:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A17570008
- Референтен број:
- 21633
- Ажурирање:
- последно на 06.08.2025
Опис
Chilworth JCI 164 High-Voltage Adapter
General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.
Combined with our JCI 140, the system enables the measurement of current-carrying conductors with voltages up to ±60 kV DC through direct connection with an accuracy of ±2% (nominal) and minimal loading effects on the device under test.
The high input impedance and low capacitance of the JCI 146 are suitable for more accurate DC voltage measurements.
Other conventional techniques for directly measuring high voltages (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often produce inaccurate results due to loading effects caused by the test setup.
This device can be used to verify the calibration and accuracy of high-voltage sources by power utilities, calibration test houses, and cable manufacturers, to name a few applications.
Features
Direct measurement of live conductors up to ± 60 kV DC
High-accuracy measurement with minimal loading effects
Low input capacitance
Very high input impedance, typically 10 13 ohms
Can be used in a wider range of test and research systems
Iasdpfxou Ehh Ee Afxsr
Optional battery-powered and opto-isolated data acquisition module available for remote high-voltage monitoring.
Specification
Measurement:
Maximum measurement voltage ± 60 kV DC
Input impedance:
Not less than 4.7x10 13 ohms at ± 50 kV
Input capacitance:
32 pF (± 20%) (JCI 146 chamber only)
Installation:
Fixed installation (permanent ground connection required)
Use:
Used in Faraday cage environments (not included as standard)
Accuracy:
Nominal ± 2%
Attenuation: 1/10
of the reading displayed on the JCI 140
For use with the JCI 140 static monitor and the JCI 165 data acquisition module
Find more items - new and used - in our shop!
International shipping costs upon request!
General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.
Combined with our JCI 140, the system enables the measurement of current-carrying conductors with voltages up to ±60 kV DC through direct connection with an accuracy of ±2% (nominal) and minimal loading effects on the device under test.
The high input impedance and low capacitance of the JCI 146 are suitable for more accurate DC voltage measurements.
Other conventional techniques for directly measuring high voltages (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often produce inaccurate results due to loading effects caused by the test setup.
This device can be used to verify the calibration and accuracy of high-voltage sources by power utilities, calibration test houses, and cable manufacturers, to name a few applications.
Features
Direct measurement of live conductors up to ± 60 kV DC
High-accuracy measurement with minimal loading effects
Low input capacitance
Very high input impedance, typically 10 13 ohms
Can be used in a wider range of test and research systems
Iasdpfxou Ehh Ee Afxsr
Optional battery-powered and opto-isolated data acquisition module available for remote high-voltage monitoring.
Specification
Measurement:
Maximum measurement voltage ± 60 kV DC
Input impedance:
Not less than 4.7x10 13 ohms at ± 50 kV
Input capacitance:
32 pF (± 20%) (JCI 146 chamber only)
Installation:
Fixed installation (permanent ground connection required)
Use:
Used in Faraday cage environments (not included as standard)
Accuracy:
Nominal ± 2%
Attenuation: 1/10
of the reading displayed on the JCI 140
For use with the JCI 140 static monitor and the JCI 165 data acquisition module
Find more items - new and used - in our shop!
International shipping costs upon request!
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2008
584 Огласи онлајн
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Вашиот оглас беше успешно избришан
Се случи грешка












