Stationary screwing unit screwing statioWSM Automation
Schraubstation
Stationary screwing unit screwing statio
WSM Automation
Schraubstation
VB додава се ДДВ
4.875 €
Состојба
Користено
Локација
Borken 

Сликите прикажуваат
Прикажи карта
Податоци за машината
- Ознака на машината:
- Stationary screwing unit screwing statio
- Произведувач:
- WSM Automation
- Модел:
- Schraubstation
- Состојба:
- добра (користена)
Цена и локација
VB додава се ДДВ
4.875 €
- Локација:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Повикајте
Детали за понудата
- ID на огласот:
- A7380038
- Референтен број:
- 25069
- Ажурирање:
- последно на 25.07.2025
Опис
WSM Stationary Screwdriving Unit Screwdriving Station
Chedsibichopfx Agbof
Assembly of parts for car radios and navigation systems and for testing them.
The assembly station is surrounded by a protective enclosure.
The service doors are equipped with monitoring switches with tumbler(interlock).
The doors are locked in automatic mode and can only be opened in automatic mode or in manual mode after pressing the Doors button on the control panel. Automatic mode cannot be started when the door is open.
Function sequence
The station is loaded with the pre-assembled module via the transfer conveyor.
The operating steps of the automatic station with the passage of a WT are described below.
In normal operation, all 3 stations work in parallel.
- Positioning of the WT with the preassembled assembly in St.2.1
- Lowering of the beam with the scanners and the vision sensor
- Scanning of the 3 codes (front panel, front LP, SD LP), comparison with the database
- Checking the correct latching of the FFC in the connector
- Lifting the carrier and lowering the WT onto the belt
- Positioning of the WT with the pre-assembled assembly in St.2.2
- Positioning of the screwdriver and screwing of the front LP
- Lowering the WT onto the belt
- Positioning of the WT with the pre-assembled assembly in pc.2.3
- Lowering of the light protection cover and contacting, positioning of the carrier with the test sensors from below
- type-dependent testing of the SD + CD lighting slots and pushbuttons
- Function test CD eject button
- Lowering the WT onto the conveyor > continue
If faults occur during the test, they are indicated on the display and can be rectified if possible.
To do this, switch to manual mode and open the doors. After the repair and starting of the automatic system, the WT is tested again in the station.
If no repair is possible (e.g. screw fault), the WT is marked as NOK in the control system and is not processed further.
Manual NOK marking and ejection is also possible.
Chedsibichopfx Agbof
Assembly of parts for car radios and navigation systems and for testing them.
The assembly station is surrounded by a protective enclosure.
The service doors are equipped with monitoring switches with tumbler(interlock).
The doors are locked in automatic mode and can only be opened in automatic mode or in manual mode after pressing the Doors button on the control panel. Automatic mode cannot be started when the door is open.
Function sequence
The station is loaded with the pre-assembled module via the transfer conveyor.
The operating steps of the automatic station with the passage of a WT are described below.
In normal operation, all 3 stations work in parallel.
- Positioning of the WT with the preassembled assembly in St.2.1
- Lowering of the beam with the scanners and the vision sensor
- Scanning of the 3 codes (front panel, front LP, SD LP), comparison with the database
- Checking the correct latching of the FFC in the connector
- Lifting the carrier and lowering the WT onto the belt
- Positioning of the WT with the pre-assembled assembly in St.2.2
- Positioning of the screwdriver and screwing of the front LP
- Lowering the WT onto the belt
- Positioning of the WT with the pre-assembled assembly in pc.2.3
- Lowering of the light protection cover and contacting, positioning of the carrier with the test sensors from below
- type-dependent testing of the SD + CD lighting slots and pushbuttons
- Function test CD eject button
- Lowering the WT onto the conveyor > continue
If faults occur during the test, they are indicated on the display and can be rectified if possible.
To do this, switch to manual mode and open the doors. After the repair and starting of the automatic system, the WT is tested again in the station.
If no repair is possible (e.g. screw fault), the WT is marked as NOK in the control system and is not processed further.
Manual NOK marking and ejection is also possible.
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2008
Испрати барање
Телефон & Факс
+49 2862 ... огласи
Вашиот оглас беше успешно избришан
Се случи грешка