Back-pressure steam turbine GT 500-4M+M Turbinen-Technik, Germany
GT 500-4
Back-pressure steam turbine GT 500-4
M+M Turbinen-Technik, Germany
GT 500-4
Година на производство
2013
Состојба
Користено
(целосно функционален)
Локација
Nideggen 

Основни податоци
- Ознака на машината:
- Back-pressure steam turbine GT 500-4
- Произведувач:
- M+M Turbinen-Technik, Germany
- Модел:
- GT 500-4
- Година на производство:
- 2013
- Состојба:
- половен
- Функционалност:
- целосно функционален
- Работни часови:
- 73.000 h
Цена и локација
- Локација:
- Hindenburgstraße 3, 52385 Nideggen, Deutschland

Повикајте
Технички детали
Мотор и менувач
Произведувач на мотори:
M+M Turbinen-Technik
Детали за моќност
Излезна фреквенција:
50 Hz
Дополнителни детали
Моќ:
7.130 kW (9.694,09 коњски сили)
Континуирана моќ:
7.130 kW (9.694,09 коњски сили)
Номинална моќност:
7.130 kW (9.694,09 коњски сили)
Максимална брзина на вртење:
1.500 обр/мин
Детали за понудата
- ID на огласот:
- A22834395
- Референтен број:
- EQ-707
- Ажурирање:
- последно на 28.09.2026
Опис
Evaporation pressure: 21 bar
Steam pressure: 4.3 bar
Temperature: Inlet 365 °C / Outlet 165 °C
Generator: 8300 kWel
Operating hours (annually): 8760 h/year
Transformers included: Siemens Type 4GU6043-9HY
Total operating hours: 73,000 h
Hedpfez E Nh Nsx Abuefn
M+M turbines are typically custom-made industrial steam turbines used for combined heat and power (CHP) or for energy recovery from process steam.
Due to the moderate inlet pressure and the relatively high outlet pressure, this is a back pressure steam turbine. It was designed for process steam systems to ensure efficient energy recovery and heat supply.
The turbine was used in a paper mill to increase efficiency.
With an output of 7.2 MW, this turbine is considered a medium-sized system in industrial applications.
Thanks to the pressure ratios and the use of the turbine's exhaust steam, very little energy is lost.
The estimated steam flow rate is 30 to 40 t/h.
This enabled the paper mill to achieve an efficiency of 60% to 75%.
The efficiency in CHP operation was approximately 75% to 85%.
The turbine was designed for operation for 8,760 hours (full load year) with a maximum steam flow rate of 114 t/h.
The turbine-generator unit supplies the paper machine with electricity at the 6 kV level. The process steam required for production is provided in two pressure stages.
As the steam flows through the turbine, the steam pressure is reduced from 20 bar to 4.2 bar.
If the turbine needs to be shut down for any reason, the process steam supply is provided via four pressure reducing stations connected in parallel.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Steam pressure: 4.3 bar
Temperature: Inlet 365 °C / Outlet 165 °C
Generator: 8300 kWel
Operating hours (annually): 8760 h/year
Transformers included: Siemens Type 4GU6043-9HY
Total operating hours: 73,000 h
Hedpfez E Nh Nsx Abuefn
M+M turbines are typically custom-made industrial steam turbines used for combined heat and power (CHP) or for energy recovery from process steam.
Due to the moderate inlet pressure and the relatively high outlet pressure, this is a back pressure steam turbine. It was designed for process steam systems to ensure efficient energy recovery and heat supply.
The turbine was used in a paper mill to increase efficiency.
With an output of 7.2 MW, this turbine is considered a medium-sized system in industrial applications.
Thanks to the pressure ratios and the use of the turbine's exhaust steam, very little energy is lost.
The estimated steam flow rate is 30 to 40 t/h.
This enabled the paper mill to achieve an efficiency of 60% to 75%.
The efficiency in CHP operation was approximately 75% to 85%.
The turbine was designed for operation for 8,760 hours (full load year) with a maximum steam flow rate of 114 t/h.
The turbine-generator unit supplies the paper machine with electricity at the 6 kV level. The process steam required for production is provided in two pressure stages.
As the steam flows through the turbine, the steam pressure is reduced from 20 bar to 4.2 bar.
If the turbine needs to be shut down for any reason, the process steam supply is provided via four pressure reducing stations connected in parallel.
Огласот е автоматски преведен. Можно е да има грешки во преводот.
Документи
Доставувач
Забелешка: Регистрирајте се бесплатно или најавете се, за пристап до сите информации.
Регистриран од: 2026
1 Оглас онлајн
Испрати барање
Телефон & Факс
+49 2427 ... огласи
Овие огласи исто така може да ве заинтересираат.
Успешно
Вашата порака е испратена.
Мал оглас
Cloppenburg
1.619 km
ALSTOMLeistungstrafo 20/25 MVA | 110kV / 20kV
Успешно
Вашата порака е испратена.
Мал оглас
Elmstein
1.380 km
Dutch DryersDX - 3000
Успешно
Вашата порака е испратена.
Мал оглас
Krotoszyn
1.170 km
FKILincoln
Успешно
Вашата порака е испратена.
Мал оглас
Tatabánya
716 km
ABB RoboterIRB 6400 Punktschweißroboter (1004)
Успешно
Вашата порака е испратена.
Мал оглас
Hamburg
1.582 km
Генератор за итни случаи од 135 kVA
Newpower Generator StromaggregatNWR150 Notstrmaggregat Diesel Generator
Newpower Generator StromaggregatNWR150 Notstrmaggregat Diesel Generator
Успешно
Вашата порака е испратена.
Мал оглас
Area P.i.p
1.042 km
JenbacherJGS 620 / 624 GS-N.L
Успешно
Вашата порака е испратена.
Мал оглас
Newton Aycliffe
2.239 km
BIODIESEL FUELS EQUIPMENT10,000 litres / 8 hour day
Успешно
Вашата порака е испратена.
Мал оглас
Varberg
1.853 km
Vecoplan + Hammarmills CPM + Filter JFKVHZ 1300
Успешно
Вашата порака е испратена.
Мал оглас
Vilnius
1.479 km
Brunette
Успешно
Вашата порака е испратена.
Мал оглас
Hamburg
1.582 km
Newpower 40kW 50kVA NotstromaggregatNWK55 Notstromaggregat mit Schallschutz
Вашиот оглас беше успешно избришан
Се случи грешка






































































































































